Available LIDs

This is a comprehensive list of HW 4.0, HW 4.1, HW 4.2 polyphase (PP), and HW 4.2 singlephase (SP) 2S meter socket LIDs available for reading in the SDK and through the metering API. The table provides indication for which meter platforms support which LIDs.

ILID name

ILID
number

HW 4.0

HW 4.1

HW 4.2 (PP)

HW 4.2 (SP)

ILID_INS_FREQUENCY

18153518u

X

X

X

X

ILID_INS_TEMPERATURE_CELCIUS

18153533u

ü

ü

ü

ü

ILID_INS_CURRENT_A

18153515u

ü

ü

ü

ü

ILID_INS_CURRENT_B

18153516u

ü

ü

ü

ü

ILID_INS_CURRENT_C

18153517u

ü

ü

ü

ü

DI_INS_CURRENT_FUNDAMENTAL_A

44761117u

ü

ü

X

X

DI_INS_CURRENT_FUNDAMENTAL_B

44761118u

ü

ü

X

X

DI_INS_CURRENT_FUNDAMENTAL_C

44761119u

ü

ü

X

X

ILID_INS_VOLTS_A

18153520u

ü

ü

ü

ü

ILID_INS_VOLTS_B

18153521u

ü

ü

ü

ü

ILID_INS_VOLTS_C

18153522u

ü

ü

ü

ü

DI_INS_VOLTS_FUNDAMENTAL_A

44761120u

ü

ü

X

X

DI_INS_VOLTS_FUNDAMENTAL_B

44761121u

ü

ü

X

X

DI_INS_VOLTS_FUNDAMENTAL_C

44761122u

X

X

X

X

ILID_INS_POWER_FACTOR

18153559u

ü

ü

ü

ü

ILID_INS_POWER_FACTOR_PHA

18153918u

X

X

ü

ü

ILID_INS_POWER_FACTOR_PHB

18153919u

X

X

ü

ü

ILID_INS_POWER_FACTOR_PHC

18153920u

X

X

ü

ü

DI_INS_POWER_FACTOR_FUNDAMENTAL_PHA

44761123u

ü

ü

X

X

DI_INS_POWER_FACTOR_FUNDAMENTAL_PHB

44761124u

ü

ü

X

X

DI_INS_POWER_FACTOR_FUNDAMENTAL_PHC

44761125u

X

X

X

X

DI_INS_POWER_FACTOR_FUNDAMENTAL_AGGREGATE

44761126u

ü

ü

X

X

ILID_INS_VAS_AGGREGATE

18153530u

ü

ü

ü

ü

ILID_INS_VAB_ANGLE

18153644u

ü

ü

ü

ü

ILID_INS_VOLTS_ANGLE_BA

18153644u

ü

ü

ü

ü

ILID_INS_VAC_ANGLE

18153645u

ü

ü

ü

ü

ILID_INS_VOLTS_ANGLE_CA

18153645u

ü

ü

ü

ü

ILID_NEUTRAL_CURRENT_MEASURED

18153652u

X

X

X

X

ILID_NEUTRAL_CURRENT_CALCULATED

18153653u

X

X

X

X

ILID_NEUTRAL_CURRENT_TAMPER

18153654u

X

X

X

X

ILID_INS_W_PHA

18153658u

ü

ü

ü

ü

ILID_INS_W_PHB

18153659u

ü

ü

ü

ü

ILID_INS_W_PHC

18153660u

ü

ü

ü

ü

ILID_INS_W_AGGREGATE

18153531u

ü

ü

ü

ü

ILID_INS_WATTS_AGGREGATE

18153531u

ü

ü

ü

ü

ILID_INS_W_FUNDAMENTAL_PHA

44761127u

ü

ü

X

X

ILID_INS_W_FUNDAMENTAL_PHB

44761128u

ü

ü

X

X

ILID_INS_W_FUNDAMENTAL_PHC

44761129u

ü

ü

X

X

ILID_INS_W_FUNDAMENTAL_AGGREGATE

44761130u

ü

ü

X

X

ILID_INS_VA_PHA

18153655u

ü

ü

ü

ü

ILID_INS_VA_PHB

18153656u

ü

ü

ü

ü

ILID_INS_VA_PHC

18153657u

ü

ü

ü

ü

DI_INS_VA_ARITH_AGGREGATE

44761141u

ü

ü

ü

ü

DI_INS_VA_VECTORAL_AGGREGATE

44761142u

X

X

X

X

DI_INS_VA_LAG_AGGREGATE

44761143u

X

X

X

X

DI_INS_VA_FUNDAMENTAL_PHA

44761131u

ü

ü

X

X

DI_INS_VA_FUNDAMENTAL_PHB

44761132u

ü

ü

X

X

DI_INS_VA_FUNDAMENTAL_PHC

44761133u

ü

ü

X

X

DI_INS_VA_FUNDAMENTAL_ARITH_AGGREGATE

44761134u

ü

ü

X

X

DI_INS_VA_FUNDAMENTAL_VECTORAL_AGGREGATE

44761135u

ü

ü

X

X

DI_INS_VA_FUNDAMENTAL_LAG_AGGREGATE

44761136u

ü

ü

X

X

ILID_INS_VAR_PHA

18153661u

ü

ü

ü

ü

ILID_INS_VAR_PHB

18153662u

ü

ü

ü

ü

ILID_INS_VAR_PHC

18153663u

ü

ü

ü

ü

ILID_INS_VAR_AGGREGATE

18153532u

X

X

X

X

ILID_INS_VAR_FUNDAMENTAL_PHA

61137u

X

X

X

X

ILID_INS_VAR_FUNDAMENTAL_PHB

61138u

X

X

X

X

ILID_INS_VAR_FUNDAMENTAL_PHC

61139u

X

X

X

X

ILID_INS_VAR_FUNDAMENTAL_AGGREGATE

61140u

X

X

X

X

ILID_CPC_DATA_INSTLOADVOLTAGEPHA

18153795u

X

X

ü

ü

ILID_INS_LOAD_VOLTAGE_PHA

18153795u

X

X

ü

ü

ILID_CPC_DATA_INSTLOADVOLTAGEPHB

18153796u

X

X

ü

ü

ILID_INS_LOAD_VOLTAGE_PHB

18153796u

X

X

ü

ü

ILID_CPC_DATA_INSTLOADVOLTAGEPHC

18153797u

X

X

ü

ü

ILID_INS_LOAD_VOLTAGE_PHC

18153797u

X

X

ü

ü

ILID_INS_CURRENT_ANGLE_PHA

18153839u

X

X

ü

ü

ILID_INS_CURRENT_ANGLE_PHB

18153840u

X

X

ü

ü

ILID_INS_CURRENT_ANGLE_PHC

18153841u

X

X

ü

ü

ILID_WH_A_DELIVERED

18153472u

ü

ü

X

X

ILID_WH_B_DELIVERED

18153489u

ü

X

ü

ü

ILID_WH_C_DELIVERED

18153490u

ü

X

ü

ü

ILID_WH_RECEIVED

18153475u

ü

ü

ü

ü

ILID_WH_A_RECEIVED

18153494u

ü

X

ü

ü

ILID_WH_B_RECEIVED

18153495u

ü

X

ü

ü

ILID_WH_C_RECEIVED

18153496u

ü

X

ü

ü

ILID_WH_NET

18153483u

ü

ü

ü

ü

ILID_WH_A_NET

18153944u

ü

X

ü

ü

ILID_WH_B_NET

18153945u

ü

X

ü

ü

ILID_WH_C_NET

18153946u

ü

X

ü

ü

ILID_INS_THDV_A

18153975u

X

X

ü

ü

ILID_INS_THDV_B

18153976u

X

X

ü

ü

ILID_INS_THDV_C

18153977u

X

X

ü

ü

ILID_INS_THDI_A

18153978u

X

X

ü

ü

ILID_INS_THDI_B

18153979u

X

X

ü

ü

ILID_INS_THDI_C

18153980u

X

X

ü

ü

DI_INS_IEC_VOLTAGE_THD_N_PHA

44761144u

X

X

X

X

DI_INS_IEC_VOLTAGE_THD_N_PHB

44761145u

X

X

X

X

DI_INS_IEC_VOLTAGE_THD_N_PHC

44761146u

X

X

X

X

DI_INS_NUMERIC_CURRENT_PHA

44761147u

X

X

X

X

DI_INS_NUMERIC_CURRENT_PHB

44761148u

X

X

X

X

DI_INS_NUMERIC_CURRENT_PHC

44761149u

X

X

X

X

ILID_VAH_DELIVERED

18153474u

ü

ü

ü

ü

ILID_VAH_A_DELIVERED

18153935u

ü

X

ü

ü

ILID_VAH_B_DELIVERED

18153936u

ü

X

ü

ü

ILID_VAH_C_DELIVERED

18153937u

ü

X

ü

ü

ILID_VAH_RECEIVED

18153477u

ü

ü

ü

ü

ILID_VAH_A_RECEIVED

18153938u

ü

X

ü

ü

ILID_VAH_B_RECEIVED

18153939u

ü

X

ü

ü

ILID_VAH_C_RECEIVED

18153940u

ü

X

ü

ü

ILID_VARH_DELIVERED

18153473u

ü

ü

ü

ü

ILID_VARH_RECEIVED

18153476u

ü

ü

ü

ü

ILID_LAST_BLURT_REAL_TIME_IN_MS

18153640u

ü

ü

ü

ü

ILID_LAST_BLURT_CONTINUOUS_TIME_IN_MS

18153639u

ü

ü

ü

ü

ILID_ACT_NETWORK_TIME

43060152u

ü

ü

X

X

ILID_CONTINUOUS_TIME_IN_MS

1083965462u

ü

ü

ü

ü

DI_WH_DELIVERED_TIER_A

44762088u

X

X

X

X

DI_WH_DELIVERED_TIER_B

44762089u

X

X

X

X

DI_WH_DELIVERED_TIER_C

44762090u

X

X

X

X

DI_WH_DELIVERED_TIER_D

44762091u

X

X

X

X

DI_WH_DELIVERED_TIER_E

44762092u

X

X

X

X

DI_WH_DELIVERED_TIER_F

44762093u

X

X

X

X

DI_WH_DELIVERED_TIER_G

44762094u

X

X

X

X

DI_WH_DELIVERED_TIER_H

44762095u

X

X

X

X

DI_WH_RECEIVED_TIER_A

44762096u

X

X

X

X

DI_WH_RECEIVED_TIER_B

44762097u

X

X

X

X

DI_WH_RECEIVED_TIER_C

44762098u

X

X

X

X

DI_WH_RECEIVED_TIER_D

44762099u

X

X

X

X

DI_WH_RECEIVED_TIER_E

44762100u

X

X

X

X

DI_WH_RECEIVED_TIER_F

44762101u

X

X

X

X

DI_WH_RECEIVED_TIER_G

44762102u

X

X

X

X

DI_WH_RECEIVED_TIER_H

44762103u

X

X

X

X

ILID_INSTRUMENTDATA_RATED_VOLTAGE

18153619u

X

X

ü

ü

ILID_INSTRUMENTDATA_RATED_CURRENT

18153620u

ü

ü

ü

ü

ILID_DEMAND_MAX_AGG_W_DEL

39059456u

X

X

ü

ü

ILID_DEMAND_MAX_AGG_W_REC

39059459u

X

X

X

X

ILID_BASE_METER_CLASS

18153547u

ü

ü

ü

ü

ILID_BASE_METER_FORM

18153550u

ü

ü

ü

ü

ILID_BASE_METER_TYPE

18153836u

ü

ü

ü

ü

ILID_BASE_METER_NUMBER_PHASES

18153557u

ü

ü

ü

ü

ILID_BASE_SERVICE_TYPE

18153545u

ü

ü

ü

ü

ILID_EQUIPMENT_IDENTIFIER

25231361u

ü

ü

ü

ü

ILID_UTILITY_SERIAL_NUMBER

25231360u

ü

ü

ü

ü

ILID_MANUFACTURER_SERIAL_NUMBER

1083965456u

ü

ü

ü

ü

ILID_INSTRUMENTSETTINGS_CURRENT_TFMR_NUMERATOR

18153609u

ü

ü

ü

ü

ILID_INSTRUMENTSETTINGS_VOLTAGE_TFMR_NUMERATOR

18153610u

ü

ü

ü

ü

ILID_INSTRUMENTSETTINGS_CURRENT_TFMR_DENOMINATOR

18153612u

ü

ü

ü

ü

ILID_INSTRUMENTSETTINGS_VOLTAGE_TFMR_DENOMINATOR

18153613u

ü

ü

ü

ü

ILID_BASE_PACKET_TYPE

18153819u

ü

ü

ü

ü

ILID_PHASE_A_NOMINAL_VOLTAGE

18153832u

ü

ü

ü

ü

ILID_PHASE_B_NOMINAL_VOLTAGE

18153833u

ü

ü

ü

ü

ILID_PHASE_C_NOMINAL_VOLTAGE

18153834u

ü

ü

ü

ü

ILID_NGC_MAC

43061155u

ü

ü

X

X

ILID_SYSTEM_FW_VERSION

1083965465u

ü

ü

ü

ü

ILID_DATASERVER_APPSERV_FW_VERSION

44761103

X

X

X

ü